Theatre & Critical Care

Patient Monitor (8 inch)

In Stock
Features:
- 8" color TFT LCD screen, resolution 800*600
- Waterproof design, resistance to dropping (1 meter)
- Low power consumption, fanless structure which creates no noise
- Support external 13-20V DC power, continuously working for 5.5 hours above on battery backup, full charge with 2.5 hours, suitable for Ambulance, Emergency Transport
- Display mode: Big font, trends review, 7 leads ECG waveform on same screen, and etc
- 15 kinds of arrhythmia analysis, 15 kinds of drug concentration analysis
- Anti-electrosurgical unit (300W), anti-defibrillation (360J), suitable for Operating Room, General Ward
- Digital SpO2 technology, excellent anti- interference performance, low perfusion (0.1%)

Specifications:

ECG
Lead: Standard 3/5 lead
Lead Mode: 5 Leads (RA, LA, LL, RL,V)
Lead Selection: I, II, III, avR, avL, avF, V
Lead Mode: 3 Leads (RA, LA, LL)
Lead Selection: I, II, III,
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
HR and Alarm Range:
Adult: 15 ~ 300 bpm
Ped/Neo: 15 ~ 350 bpm
Accuracy: ±1% or±1bpm, which is greater
Resolution: 1 bpm
Sensitivity: > 200 (uVp-p)
Differential Input Impedance: > 5 MΩ
Bandwidth:
Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
CMRR:
Monitor > 100 dB
Operation > 100 dB
Diagnosis > 90 dB
Electrode Offset Potential: ±300mV
Range: ±2 mV ~ ±700 mV
Width: 0.1 ms ~ 2 ms
Rise time: 10 us ~ 100 us
ST Segment Monitoring Range:
Measurement Range: -2.0 ~ +2.0 mV
Measurement Accuracy: -0.8 ~ +0.8 mV
Measurement Error: ±0.02 mV or ±10%

RESP
Method: Impedance Between RA-LL or RA-LA
Measuring Impedance Range: 0.3~3 Ω
Base line Impedance Range: 200~4 KΩ
Bandwidth: 0.1~2.5Hz
Resp. Rate:
Measuring and Alarm Range:
Adult: 2 ~ 120 BrPM
Neo/Ped: 2 ~ 150 BrPM
Resolution: 1 BrPM
Accuracy: ±2 BrPM
Apnea Alarm: 10 ~ 40 S

NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in Auto Mode:
1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Measuring and Alarm Range:
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Static Pressure Range: 0 ~ 300 mmHg
Static Pressure Accuracy: ±3mmHg
Accuracy: Maximum Average Error ±5mmHg
Maximum Standard Deviation ±8mmHg
Overpressure Protection:
Adult Mode: 300 mmHg
Pediatric Mode: 240 mmHg
Neonatal Mode: 150 mmHg

SpO2
Measuring Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %
0% ~ 69% unspecified
Pulse Rate:
Measuring Range: 20~300 bpm
Resolution: 1bpm
Accuracy: ±3bpm

TEMP
Applicable Temperature Sensor: YSI, CYF
Channel: 1
Measuring Range: 0 ~ 50 ℃
Resolution: ±0.1 ℃
Accuracy: ±0.1 ℃ (Do not including sensor error)

Dimension: 210*80*175mm (L*W*H)
Weight: 1.35kg

Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, 1-TEMP
Optional: Mainstream/Sidestream EtCO2, Touch screen,Wall mount, Trolley, Central station

Technical specifications for this product were not available at the time of migration.

Suitable for use in hospitals, clinics, laboratories and other healthcare facilities. Contact us for a suitability assessment for your specific application.

Domestic orders are generally processed within 2–3 business days, excluding weekends and holidays. Shipping charges are calculated at checkout or provided with your quotation.

No reviews yet for this product.