Patient Monitor (15 inch)

Category:

Features:
1.15″ high resolution color TFT LCD display;
2.13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
4. SPO2 can testing for 0.1% Weak;
5. RA-LL impedance Respiration;
6. Trend Coexist Display;
7. OxyCRG DyNamic View Display;
8. Bed to Bed view Display;
9. Networking capacity ;
10. Options of printing, IBP, VGA and EtCO2;
11. UP to 4 hours working capacity of built_in rechargeable battery;
12.15″ high resolution color TFT LCD display;
13. Large volume of tabular and graphic trends information storage and easy to recall;
14. Anti-ESU, anti- defibrillator;
15. Capture dynamic waveforms.

Technical specification

ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1 ch
Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy : ± 1% or ± 1bpm,which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 S After Defi. ECG Signal Range: ±8 m V ( Vp-p ) Bandwidth Surgery: 1 ~ 15 Hz Monitor: 0.5 ~ 35 Hz Diagnostic: 0.05 ~ 100 Hz Calibration Signal: 1 (mV p-p), Accuracy:±5% ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,
TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available

RESPARATION
Method: Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy : ±2 rpm
Apean Alarm: 10 ~ 40 S

NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution Pressure:1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg

SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy : 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy : ±2bpm

TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy : ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant:<10 Sec.

IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy : ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec

Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional: Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder, Wall mount, Trolley, Central station, HDMI

Reviews

There are no reviews yet.

Be the first to review “Patient Monitor (15 inch)”

Your email address will not be published. Required fields are marked *

Domestic Shipping Policy

Shipment processing time

All orders are processed within 2-3 business days. Orders are not shipped or delivered on weekends or holidays.

If we are experiencing a high volume of orders, shipments may be delayed by a few days. Please allow additional days in transit for delivery. If there will be a significant delay in shipment of your order, we will contact you via email or telephone.

Update this section if your processing time exceeds 2-3 business days.

Shipping rates & delivery estimates

Shipping charges for your order will be calculated and displayed at checkout.

Delivery delays can occasionally occur.

Update this section based on carriers you support.

Start typing and press Enter to search

Shopping Cart

No products in the cart.